Projects

Site Management, Health and Safety

Project Management / Site Management and Quality Control

Site Management and Quality Control

 

Clean Tanks C3001 and C3002 at DFSP Chimwan, Okinawa

  • Vent tanks
  • Perform LOTO
  • Perform Confined Space Entry
  • Enter tanks and removal of residual fuel and sludge
  • Tank cleaning in preparation for API inspection
  • Gas free certification
  • Support during API inspection
  • Tank calibration and strapping chart
  • Close tank and return to service

Site Management and Quality Control

Project Management / Site Management and Quality Control

Site Management and Quality Control

 

Clean, Inspect and Repair Tank 603, DFSP Tsurumi, Japan

  • Repair topside pit
  • Replace the external floating roof with a new aluminum honeycomb floating pan
  • Install telltale holes on reinforcing plates
  • Repair pressure relief loop at the fill and issue nozzles
  • Repair floor projection to asphalt interface
  • Re-coat entire tank interior
  • Replace existing

 

Clean, Inspect and Repair Tank 603, DFSP Tsurumi, Japan

  • Repair topside pit
  • Replace the external floating roof with a new aluminum honeycomb floating pan
  • Install telltale holes on reinforcing plates
  • Repair pressure relief loop at the fill and issue nozzles
  • Repair floor projection to asphalt interface
  • Re-coat entire tank interior
  • Replace existing aluminum geodesic dome roof with a new conventional fixed column steel roof
  • Repair product recovery system
  • Repair internal tank issue piping
  • Repair fill and issue nozzle Double Block and Bleed (DBB) valves
  • Upgrade existing Automatic Tank Gauge (ATG) and manual gauge tubes
  • Repair tank access ways per UFC 3-460-01
  • Install high level alarms per UFC 3-460-01
  • Replace existing nonoperational manual float gauge
  • Install a hydraulically operated high level shut-off valve, shell-mounted float, and
    connecting tubing
  • Install new pipeline supports
  • Install corrosion-resistant / PTFE-coated bolting hardware
  • Install UV-resistant polymer bolt protectors and flange protectors

Project Management / Site Management and Quality Control

Project Management / Site Management and Quality Control

Project Management / Site Management and Quality Control

 

Repair POL Facilities
DFSP (OU-1 and OU-2) Tsurumi, Japan

  • Demolition of existing pumps, pipe and supports
  • Pipe manifold construction
  • Pipe coating
  • Pump replacement
  • Weld testing and pipe testing
  • Civil construction and containment
  • Utilidor construction
  • Electrical construction (MCC and Emergency Shut-offs)

Project Management / Site Management and Quality Control

Project Management / Site Management and Quality Control

Project Management / Site Management and Quality Control

 

Clean, Inspect and Repair Tanks, DFSP Tsurumi, Japan

  • Tank Cleaning
  • API 653 Inspection
  • Mechanical Repairs
  • Interior and Exterior Coating
  • Tank Calibration

Project Management

Project Management / Site Management and Quality Control

Project Management

 

Repair Pipelines, POL Pier, and Other Components, Iwakuni, Japan

  • Replace all high-point vents and low-point drains
  • Repair pipeline supports
  • Pipeline re-coating
  • Pipeline cleaning via “dumb” pigging
  • Pipeline pressure testing
  • Clean strainers and replacing filter elements and other consumables during pigging

Project Management

Project Management / Site Management and Quality Control

Project Management

 

Clean, Inspect and Repair six Tanks, Sasebo, Japan

  • Coating interior (ceiling and floor) and exterior (roof and shell)
  • Repairs to access structure and handrails
  • Re-plumb several tank columns
  • Dike repairs and concrete cracks
  • Replace Level Control Valves
  • High-high level alarm repair
  • Install new Stilling wells
  • Replace Isolation valves with Double block and bleed valves

Project Management / Site Management and Quality Control

Project Management / Site Management and Quality Control

Project Management / Site Management and Quality Control

 

Emergent Pipeline Repairs, DFSP Hakozaki, Japan

  • Replace existing, damaged Expansion joints
  • Repair existing concrete pipe supports
  • Repair I-Beam Supports with new chemical anchors
  • Replace existing pipe
  • Pressure test new pipe and expansion joints
  • Coat new pipe and expansion joints

Project Management / Site Management and Quality Control

Project Management / Site Management and Quality Control

Project Management / Site Management and Quality Control

 

Repair Circulation Loop, DFSP Hachinohe, Japan

  • Replace circulation loop piping
  • Replace Double Block and Bleed Valves
  • Replace Pressure Relief Valves
  • Provide new concrete support foundations
  • Provide new vent valves
  • Coat and stencil new piping and valves
  • Pressure test circulation loop

Project Management

Project Management / Site Management and Quality Control

Project Management

 

Repair Pipelines

DFSP Diego Garcia

  • Install thermal relief bypass piping
  • Replace 16in main tank farm header and DBB valves
  • Excavate and replace Low Point Drains
  • Survey of entire piping system and corrosion/pitting repairs
  • Pipe penetration repairs through tank containment walls
  • New pipe supports and u-bolt installation